Hi folks,
Beam 2 injection: the nominal strength is 51.310 kV for a total angle with 4 magnets of 0.822 mrad, (to inject onto the central orbit with no bumps etc) .
We can assume the voltage range needed will be between 48 kV and 54 kV. This gives us a worst-case minimum of 27 urad strength in reserve.
Can you do the necessary in the SoftStart and RBAC settings?
Cheers Brennan
Required system kick (rad) |
0.000821818 |
Required magnet kick (rad) |
0.000205454 |
B.rho at 450 GeV (T.m) |
1503.17 |
MKI TF (Tm/kV) |
0.006019 |
MKI TF (rad/kV) |
4.0042E-06 |
System TF (rad/kV) |
1.60168E-05 |
Required magnet strength (T.m) |
0.308832861 |
Required V nom (kV) |
51.310 |
Possible Field error (kV) |
1.026 |
Possible V nom max (kV) |
52.336 |
V max (kV) |
54.000 |
Trimming range (kV) |
1.664 |
Trimming range rad (system) |
2.6654E-05 |